logo
Changsha GOMECY Electronics Limited
Ürünler
Ürünler
Ev > Ürünler > fraksiyonel CO2 lazer makinesi > Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy

Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy

Ürün Detayları

Menşe yeri: Pekin

Marka adı: GOMECY

Sertifika: CE

Model numarası: GMS C5 Dikey

Ödeme ve Gönderim Koşulları

Min sipariş miktarı: 1

Fiyat: USD 5299~5899

Ambalaj bilgileri: Alüminyum kutusu

Teslim süresi: 5-7 gün

Ödeme koşulları: T/T, Western Union, MoneyGram

Yetenek temini: Ayda 500 PC

En İyi Fiyatı Alın
Vurgulamak:
Ürün adı:
fraksiyonel co2 lazer
Teknoloji:
Tıbbi CO2 lazer makinesi
İşlev:
Dermatoloji CO2 lazer
Çalışma modu:
Tek darbe, sürekli nabız, tekrarlanan nabız
Lazer tipi:
metal tüp
Lazer dalga boyu:
10600nm
Çıktı gücü:
60W
Giriş gücü:
450VA
İşlem Modları:
Darbeli, ultra darbeli, sürekli
Nabız genişliği:
0.02-0.99s
Nabız süresi:
1-100μs
Tarama Desenleri:
Üçgen, kare, dikdörtgen, elmas, çizgi, yuvarlak
ışın sapması:
4mrad
Odaklanmış nokta çapı:
120-240μm
Hedefleme kirişi:
Kızılötesi ışın (630-650nm, <5MW)
Işın Teslimatı:
7-eklemli kol, 360 ° rotasyon
Soğutma sistemi:
Dahili Dolaşım Soğutma
Ekran ekranı:
Gerçek renk LCD dokunmatik ekran
Çalışma sistemi:
Mikrobilgisayar kontrolü
Giriş voltajı:
AC220V ±%10, 50Hz
Sondalar:
Tarayıcı probu, vajinal prob, cerrahi prob
Ürün adı:
fraksiyonel co2 lazer
Teknoloji:
Tıbbi CO2 lazer makinesi
İşlev:
Dermatoloji CO2 lazer
Çalışma modu:
Tek darbe, sürekli nabız, tekrarlanan nabız
Lazer tipi:
metal tüp
Lazer dalga boyu:
10600nm
Çıktı gücü:
60W
Giriş gücü:
450VA
İşlem Modları:
Darbeli, ultra darbeli, sürekli
Nabız genişliği:
0.02-0.99s
Nabız süresi:
1-100μs
Tarama Desenleri:
Üçgen, kare, dikdörtgen, elmas, çizgi, yuvarlak
ışın sapması:
4mrad
Odaklanmış nokta çapı:
120-240μm
Hedefleme kirişi:
Kızılötesi ışın (630-650nm, <5MW)
Işın Teslimatı:
7-eklemli kol, 360 ° rotasyon
Soğutma sistemi:
Dahili Dolaşım Soğutma
Ekran ekranı:
Gerçek renk LCD dokunmatik ekran
Çalışma sistemi:
Mikrobilgisayar kontrolü
Giriş voltajı:
AC220V ±%10, 50Hz
Sondalar:
Tarayıcı probu, vajinal prob, cerrahi prob
Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy

Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy 0

1. What is CO₂ Laser Technology?

The CO₂ laser is a high-energy system that emits light at a wavelength of 10600nm, which is strongly absorbed by water in biological tissues. Because human skin and mucosa are rich in water, this laser is highly effective in cutting, vaporizing, and coagulating soft tissue with excellent precision.

The device uses fractional scanning technology and different probes to adapt to dermatology, gynecology, and surgical procedures.

  • In dermatology, the fractional CO₂ laser creates microthermal zones in the skin, stimulating collagen regeneration and improving skin texture, wrinkles, scars, and pigmentation.

  • In gynecology, the CO₂ vaginal probe promotes mucosal regeneration, improves tissue elasticity, and restores vaginal health.

  • In surgery, the precise cutting ability allows minimally invasive operations with reduced bleeding and faster healing.

This combination of applications makes it a versatile solution for clinical and cosmetic needs.

2. Applications

Dermatology

  • Skin resurfacing and rejuvenation

  • Reduction of fine lines and wrinkles

  • Scar improvement (acne scars, surgical scars, burn scars)

  • Pigmentation treatment

  • Skin tightening and pore reduction

Gynecology

  • Vaginal tightening and rejuvenation

  • Improvement of dryness and laxity

  • Postpartum tissue restoration

  • Supportive therapy for mild incontinence

Surgery

  • Cutting and vaporization of soft tissue

  • Coagulation to reduce bleeding

  • Precise excision with minimal damage to surrounding tissue

3. Product Parameters

Parameter Specification
Working Mode Single pulse, Continuous pulse, Repeated pulse
Laser Type Metal Tube
Laser Wavelength 10600nm
Output Power 60W
Input Power 450VA
Operation Modes Pulsed, Ultra Pulsed, Continuous
Pulse Width 0.02–0.99s
Pulse Duration 1–100μs
Scan Patterns Triangle, Square, Rectangle, Diamond, Line, Round
Beam Divergence 4mrad
Focused Spot Diameter 120–240μm
Aiming Beam Infrared Ray (630–650nm, <5mW)
Beam Delivery 7-joint articulated arm, 360° rotation
Cooling System Internal circulation cooling
Display Screen True color LCD touch screen
Operation System Microcomputer control
Input Voltage AC220V ±10%, 50Hz
Probes Scanner probe, Vaginal probe, Surgical probe

4. Product Features

  • Versatile Probes: Equipped with scanner, gynecological, and surgical handpieces.

  • Fractional Scanning: Adjustable scan patterns and spot sizes for tailored treatments.

  • Precision Cutting: Ultra-pulsed mode for delicate surgical applications.

  • Smart Control System: Microcomputer-based, user-friendly interface.

  • Efficient Cooling: Built-in circulation ensures stable performance.

  • Ergonomic Design: 7-joint articulated arm provides flexibility and accuracy.

5. Treatment Steps

Dermatology (fractional resurfacing)

  1. Cleanse the treatment area.

  2. Apply topical anesthesia if needed.

  3. Select scan pattern, energy level, and pulse duration.

  4. Deliver fractional CO₂ laser to target area.

  5. Apply cooling gel or soothing mask after treatment.

Gynecology

  1. Gynecological evaluation and patient preparation.

  2. Apply local anesthesia or numbing gel if required.

  3. Insert vaginal probe gently.

  4. Deliver laser energy in fractional mode for mucosal stimulation.

  5. Patient may resume normal activity within 1–2 days.

Surgery

  1. Prepare surgical site under aseptic conditions.

  2. Adjust laser mode (pulsed, continuous, or ultra-pulsed).

  3. Perform incision, vaporization, or coagulation as needed.

  4. Minimal bleeding due to coagulation effect.

  5. Postoperative dressing and care.

6. Pre-Treatment Guidelines

  • Avoid sun exposure and tanning for at least 2 weeks before treatment.

  • Do not use retinoids or exfoliating agents 1 week prior.

  • Inform the doctor about any medications or medical history.

  • For gynecology, ensure no active infection or menstruation period.

7. Post-Treatment Care

  • Apply prescribed soothing ointments to the treated area.

  • Avoid hot baths, sauna, and strenuous exercise for 1 week.

  • Keep the treated skin clean and moisturized.

  • Use sunscreen daily to prevent pigmentation.

  • For gynecological procedures, avoid activity for 5–7 days.

8. Contraindications

  • Pregnancy and breastfeeding

  • Severe systemic diseases (uncontrolled diabetes, cardiovascular conditions)

  • Active infections or open wounds at the treatment site

  • History of keloid formation or abnormal scarring

  • Blood clotting disorders or use of anticoagulants

Medical Fractional CO2 Laser Device With Vaginal Probe For Gynecology Rejuvenation Skin Tightening And Pigmentation Therapy 1